Teledyne LeCroy WaveAce 222 Oscilloscope (200 MHz, 2 GS/s, 2 channels)
Manufacturer: LECROY Model: WaveAce 222 - Request a Quotation
- Contact
Vertical System | |
Bandwidth | 200 MHz |
Rise time | 1.8 ns |
Input Channels | 2 |
Bandwidth Limiters | 20 MHz |
Input Impedance | 1 MΩ ± 2% || 13 pF ± 3 pF, 50 Ω ± 2% |
Input Coupling | AC, DC, GND |
Maximum Input Voltage | 1 MΩ: ± 400 Vpk, 50 Ω: 5 VRMS |
Channel-Channel Isolation | ≥ 100:1 at 100 MHz |
Vertical Resolution | 8 bits |
Sensitivity | 2 mV/div - 5 V/div |
DC Gain Accuracy | ±3%: 5 mV/div - 5 V/div (fixed gain ranges) ±4%: 2mV/div and variable gain ranges |
Offset Range | ±800 mV: 2mV/div - 100 mV/div ±40V: 102 mV/div - 5 V/div |
Horizontal System | |
Time/Division Range | 2.5 ns/div - 50 s/div |
Clock Accuracy | 100 ppm |
Trigger and Interpolator Jitter | .5 ns (pk-pk) |
Acquisition System | |
Single-Shot Sample Rate/Ch | 2 GS/s on 1 Ch 1 GS/s on 2 Ch |
Equivalent Sample Rate | 50 GS/s |
Memory | 18 kpts/Ch on 1 Ch 9 kpts/ch on 2 Ch |
Acquisition Modes | |
Averaging | Selectable Number of Sweeps: 4, 16, 32, 64, 128, 256 |
Peak Detect | 2.5 ns |
Interpolation | Linear, Sin x/x |
Enhanced Resolution | na |
Sequence Mode | na |
Triggering System | |
Modes | Normal, Auto, Single, Stop |
Sources | Ch 1 - Ch 2, EXT, EXT/5, AC Line |
Coupling Mode | AC, DC, LF Rej, HF Rej, |
Pre-trigger Delay | memory/(2 * sample rate) |
Post-trigger Delay | 260 Divisions |
Hold-off by Time or Events | 100 ns - 1.5 s |
Internal Trigger Range | ±6 divisions from center |
Trigger Sensitivity | 1 division: DC - 10 MHz 1.5 divisions: 10 MHz - 200 MHz |
External Trigger Sensitivity | Ext: 200 mVpp from DC to 10 MHz 300 mVpp from 10 MHz to 200 MHz Ext/5: 1Vpp from DC to 10 MHz 1.5 mVpp from 10 MHz to 200 MHz |
External Trigger Input Range | Ext: ±1.2 V, EXT/5: ±6 V |
Display | |
Type | Color 5.7" TFT-LCD |
Resolution | QVGA; 320 x 234 pixels |
Grid Styles | YT (12 horizontal divisions), XY |
Trigger Types | |
Optional Advanced Triggers | na |
Optional Serial Data Triggers | na |
Internal Storage | |
Waveform Storage | 20 waveforms and 2 reference waveforms |
Setup Storage | 20 setups |
Math | |
Number of Math Traces | 1 |
Standard Math Functions | Add, Subtract, Multiply, Divide, FFT |
Optional Math Functions | na |
Measurements | |
Number of Measurements Displayed | 5 |
Measurement Parameters | Amplitude, Average, Base, Burst Width, Cyclical RMS, +Duty Cycle, -Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Rise Time, RMS, Top, +Width, -Width, First Rising-Rising, First Rising-Falling, First Falling-Rising, First Falling-Falling, Last Rising-Rising, Last Rising-Falling, Last Falling-Rising, Last Falling-Falling |
Probes | |
Probes | Qty. (2) ÷10/1 Passive Probes |
Scale Factors | Manual: ÷1, ÷10, ÷100, ÷1000 |
Calibration Output | 1 kHz square wave, 3Vp-p (typical), output to probe hook |
Interface | |
GPIB Port (optional) | na |
USB (Device) | 1 |
Ethernet Port | na |
USB (Host) | 1 |
Serial Port | 1 |
Power Requirements | |
Voltage | 100 - 240 VAC, 45 Hz to 440 Hz |
Max. Power Consumption | 50 VA |
Environmental and Safety | |
Temperature (Operating) | 10 °C to 40 °C |
Temperature (Non-Operating) | -20 °C to 60 °C |
Humidity (Operating) | 85% RH, 40 °C |
Humidity (Non-Operating) | 85% RH, 65 °C |
Altitude (Operating) | 3000 m |
Altitude (Non-Operating) | 15,266 m |
Physical Dimensions | |
Dimensions (HWD) | 154 mm x 305 mm x 133 mm (6" x 12" x 5.25") |
Weight | 2.3 kg (5 lbs) |
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment