SKY NG RADIO is a high voltage line detector : medium voltage (< 50 kV) and high voltage (> 50 kV).
SKY NG RADIO operates on a proximity detection principle using several sensors, depending on the number of arms on the machine.
It warns the operator by an audible signal and a warning light when the high lift equipment enters a high risk zone, with a warning distance that can be configured between 3 to 6 meters (10 to 17 feet) from a high voltage line.
SKY NG RADIO is designed for concrete belts, pumps, mixer-pumps, auxiliary cranes, etc.
OPERATING
SKY NG RADIO activates when the power take-off is engaged.
The electrical field detection activates the audible alarms and visual alarms and can cause the stop of the motion (with effective cabling).
The driver can turn off the audible alarm and the motion stopping (if effective) features for an hour by pushing the button “call-back mode”.
The buzzers and the flashing lights remain active.
After an hour, the system resets.
TECHNICAL CARACTERISTICS
– For a multi-sensors configuration, the configurable detection threshold upon installation varies from 3 to 6 meters (10 to 17 feet) from a high voltage line.
– Measurement precision : ± 1 meter (3 feet) while moving, with a speed of 1 m/s (3.3 feet/s).
– Power supply : 24 VDC or 12 VDC.
– Size : 160 x 85 x 45 mm (sensor), 160 x 130 x 60 mm (central unit), 145 x 85 x 90 mm (inside box of visualization) and 120 x 80 x70 mm (outside box of visualization).
– Waterproof standard : IP65
– Temperature range : -20°C to +60°C.
– Self-test system at each power-on.
– The sensibility limits of the device does not allow to detect 230 V to 280 V power lines.
– The system does not detect the presence of direct current voltage.