Control system: 7-inch color touch screen+PLC
Burner
Inner diameter: Φ 0.5mm ± 0.1mm
Outer diameter: ≤Φ 0.9mm
Length: ≥35mm
Material: stainless steel
Burner angle: 450 or 900
Flame calibration system: Built-in system, PLC automatic timing judgment, automatic protection below 50°C
Timer
Integrated in PLC
Accuracy: ±0.1s
Ignition layer: White pine board with thickness 10mm, and cover with wrapping tissue 12g/m2 ~30g/m2
Flame height: 12mm ± 1mm (adjustable)
Burn gas: ≥95% butane gas or propane gas (prepare by user)
Flame requirement: rising time from 100℃±5℃ to 700℃±3℃ should within 23.5s±1s
Thermocouple: Φ0.5mm K type thermocouple (The insulating sleeve heat resist to 1100 ℃)
Temperature sensor: Copper with Φ4±0.01mm and 0.58±0.1g weight, equip with K type thermocouple
Test space: ≥ 0.5m3 , matte black background, illuminance ≤ 20Lux, built-in exhaust fan, exhaust hole: Φ120mm
Test period: PLC auto control, with remote-controller
Pick-up tray: Yes
Gas calibration device: Built-in temperature measuring box, gas calibration can be executed before test
Accessories: Wrapping tissue, flat smooth wooden board, height gauge, lighter, remote-controller.
Standard: IEC60695-11-5 (IEC60695-2-2), IEC62368 annex S, EN60695, GB/T51669.5, GB4706.1
Equipment size: 1100mm(W)*630mm(D)*1300mm (H)
Power supply: AC220±10%, 50Hz, 0.3KVA
Needle flame tester is designed according to IEC60695-11-5 (IEC60695-2-2). It is applicable to ignition hazard test, combustibility test of electronic industry and home electronic appliance. The equipment specifies a needle-flame test to simulate the effect of a small flame which may result from fault conditions, in order to assess product and material’s ignition risk and fire resistance by a simulation technique the fire.
The Needle Flame Tester consists of a dia.0.9mm needle burner that tilts to 45 degrees from the vertical and is fueled with butane gas. The fire hazard of the specimen is assessed by measuring the burning duration of the specimen, and any ignition of the wrapping tissue and white pine board below the specimen.
The equipment is controlled by 7-inch color touch screen and PLC, the system comes with a flame calibration system. The shell is made of painted coating metal sheet and built-in air exhaust. The front panel is transparent for easy observation of the experimental process.