| Gas Detected |
All Combustible Gases (Methane as standard) |
Oxygen (O2) |
Hydrogen Sulfide (H2S) |
Carbon Monoxide (CO) |
| Detection Principle |
Catalytic combustion |
Galvanic cell |
Electrochemical cell |
| Detection Range |
0~100% LEL |
0~40.0% Vol. (0.1% Vol.) |
0~100 ppm (0.5 ppm) |
0~500 ppm (1 ppm) |
Accuracy Statement (whichever is greater) |
± 5% of reading or ± 2% LEL |
± 0.5% O2 |
± 5% of reading or ± 2 ppm H2S |
± 5% of reading or ± 5 ppm CO |
| Sampling Method |
Diffusion sampling standard / hand aspirator or motorized pump optional |
| Display |
Digital LCD displays all four gases simultaneously, with auto backlight |
| Alarm Method |
Gas alarms: 1st and 2nd (user adjustable), STEL, TWA and OVER Trouble alarms: Sensor connection, low battery, low flow, circuit trouble and calibration error
|
| Types of Alarms |
Gas Alarm: 2 increasing alarms, STEL, TWA, overscale alarm Trouble alarm: Sensor disconnection, wire disconnection, low battery, circuit error, calibration range error
|
| Operating Temp. & Humidity |
-4°F to 122°F (-20°C ~ +50°C), 0 to 95% RH, non-condensing (splash resistant) |
| Response Time |
Within 30 seconds (T90) |
| Continuous Operation |
20 hours after a 3 hour full charge (14 hours after 90 min charge) |
| Power Source |
Direct charging NiMH batteries, set of 2 |
| Safety Design |
IECEx zone 0 Ex ia IIC T4; ATEX II 1G Ex ia IIC T4; CSA classified, “C/US”, as intrinsically safe. Class I, Division 1, Groups A, B, C, D |
| Dimensions & Weight |
2.7” H x 3” W x 1” D (Approx. 70 H x 75 W x 25 D mm), 4.6 ounces (approx. 130g) |
| Case Material |
RFI shielded high impact over molded rubber. Dust and water-resistant with IP-67 approval. |
| Controls |
Two glow in the dark buttons: POWER / MODE, AIR |
| Required Accessories |
Battery charger |
| Standard Accessories |
Battery charger, Alligator clip, NiMH batteries (set of 2)
|
| Optional Accessories |
- Belt Clip
- Padded carrying case for GX-2009 and accessories
- Charging station, 115/220 VAC powered for 2, 3, 4, or 5 instruments
- Charging station with 12 VDC power supply and vehicle adapter plug
- 12 VDC adapter with vehicle plug (does not include charger base)
- RP-6 sample drawing pump with 10’ hose and probe
- Hand aspirated sample draw with 10’ hose and probe
|
| Configurations |
4 gas (LEL / O2 / H2S / CO), 3 gas (LEL / O2 / H2S), 3 gas (LEL / O2 / CO), 2 gas (LEL / O2), 2 gas (O2 / H2S), 2 gas (O2 / CO) |
| Warranty |
Two years material and workmanship
|