Output: Digital (RS-485)
Measuring range: Depends on the probe connected
Display range:
Temperature : -15 to 65.0°C
Humidity : 5 to 99.9%rh
Measuring Accuracy: Depends on the probe connected
Resolution:
Temperature: 0.1°C (at >-9.9°C); 1°C (at other range)
Humidity: 0.1%rh (at >15%rh); 1%rh(at other range)
Display accuracy:
Temperature :±(0.1+1digit)°C Humidity :±(0.1+1digit)%rh
RS-485:
Bit/sec: 9600
Data bit: 8
Stop bit: 1
Parity check: non
Power requirement: 12 to 24VDC or AC adapter (9VDC / 500mA)
Functions:
Upper/lower limit output (relay contact)
(Max. rate of alarm output: Voltage resistance: 48VAC/DC continuous load current: 1A)
Sampling( switchable at 1 sec. and 10 sec.)
Materials:
Main body: ABS resin
Display: Acryl resin
Dimensions:118(W) x 100(H) x 42(D)mm
Weight: approx. 220g
Accessories: One fixing screw to fasten the probe