For full functionality of this site it is necessary to enable JavaScript.
EMIN.COM.MM
0

Some of the simplest and most effective methods of checking coils

10/10/2024 15:43:23

Coils are one of the structural components of electrical and electronic equipment, so checking them regularly is necessary. If there is a problem with the coil, the device's performance can be affected, even leading to serious damage. Therefore, checking your coils periodically will help ensure EMIN will share some simple and easy-to-implement ways for you to effectively and easily check your coils yourself.

Check coil pulse

Normally, the wires in the coil are insulated with a specialized coating, but over time, the insulation resistance can decrease, causing a short circuit. 

The pulse testing technique works by applying a pulsed voltage to the coil, then recording the response waveform. This waveform will be compared with a sample waveform from a well-functioning motor to detect any errors or damage. In this way, it is possible to determine the condition of the coil and draw more accurate conclusions

Changes in the coil's response waveform are determined by three main factors: the inductance value (L), the resistance value (R) of the coil, and the capacitance value (C) of the motor. Judgment method through area comparison is a commonly used way to measure the difference between the waveforms of normal and defective parts. 

Some modern devices also have the ability to automatically quantify this response waveform. The inductance, resistance and capacitance values ​​of the coil play an important role in calculating and evaluating waveform changes, helping to accurately determine the condition of the motor.

Measure insulation resistance

Insulation resistance measurement evaluates the insulation condition of the windings, especially useful in testing motor windings. When the insulation of the coil is degraded, the risk of electric shock or short circuit increases significantly. 

Checking the insulation condition of the coil is essential to ensure equipment safety. If the measurement results show that the resistance of the coil reaches infinity, it can be concluded that the insulation is still guaranteed.

Conversely, if the resistance is 0 Ω, this indicates that the insulation has been compromised and is likely to cause a problem. To achieve more accurate results, you should use a device with a contact test function, which makes it easier to check for damaged wires, avoiding erroneous conclusions during the test.

Reference: Hioki ST5520 insulation resistance tester

Ability to withstand testing

As well as measuring insulation resistance, withstand voltage testing is an important test method to ensure the coil is capable of withstanding the operating voltage without insulation problems. Sometimes, we can confuse these two techniques because they both aim to ensure safety, prevent electric shock and fire. However, each technique has a different approach and purpose.

Insulation resistance testing focuses on measuring resistance values ​​to detect defects in insulation. Withstanding voltage testing goes further, using a specific voltage level, usually determined by the product's safety standards, to test whether a failure occurs when the coil is subjected to high voltage or not. From there, we can evaluate the resistance of the insulation and ensure that the device will not have problems when operating in practice.

Measure the inductor

Inductance represents the ability to create an induced electromotive force when the current changes. It can be simply understood that it is like a resistance to alternating current. Coils designed to produce inductance are often called inductors, and they come in many different types. Some coils do not use a magnetic core, but only air or non-magnetic materials. Meanwhile, other coils have cores made from magnetic materials such as ferrite, which makes their inductance depend on the current flowing through them.

Inductors with magnetic cores also have the phenomenon of self-resonance, when the inductance and parasitic capacitance of the core create a resonant frequency, called the self-resonant frequency. To accurately measure the inductance of the coil, specialized measuring equipment such as an LCR meter should be used. However, it is important that the L and Q measurements be made at a frequency low enough relative to the self-resonance frequency to ensure the highest accuracy.

Coil inspection cannot be overlooked in electronic circuits, especially when checking product quality or during equipment maintenance and repair.

Product reference: HIOKI IM3536 LCR meter

Conclude:

Above are common methods to effectively check coils. If you find it useful, please follow EMIN Fanpage to update more information!

Related News

Which Vacuum Pump Should You Choose for a Microbiology Lab to Avoid Affecting Samples?
07/15/2026 14:45:07

Vacuum pumps are utilized in a wide range of microbiology laboratory procedures, from membrane filtration and the aspiration of supernatants following centrifugation to sample concentration and the support of negative-pressure systems. Selecting the appropriate pump not only ensures more stable operational processes but also minimizes the risk of sample contamination, reduces maintenance costs, and extends the equipment's lifespan

QCVN 25:2025/BKHCN Takes Effect: Do Businesses Need to Prepare Electrical Safety Testing Equipment?
07/15/2026 09:15:04

Electrical safety is consistently one of the primary criteria evaluated before electrical or electronic equipment—or industrial components—are released to the market. A product may operate reliably yet still fail to meet requirements if its insulation lacks sufficient durability, its grounding resistance exceeds permissible limits, or leakage current occurs during operation.

Why Is Associated Research Considered an Icon of Hipot Technology?
07/14/2026 09:05:30

When it comes to electrical safety testing equipment specifically Hipot testers—many QA/QC and testing engineers are familiar with the globally renowned brand Associated Research. A subsidiary of the parent company IKONIX, Associated Research (ARI) invented the world's first commercial Hipot tester.

What Is the Standard 3-Phase Voltage? How to Read Cabinet-Mounted Meters Without Errors
07/13/2026 15:09:18

Voltmeters are almost invariably found on the panels of electrical cabinets in factories, power stations, or generator systems. A glance lasting just a few seconds allows an operator to determine whether the power supply is stable or showing signs of abnormality. However, not everyone understands the significance of the displayed readings, particularly regarding three-phase electrical systems.

Distinguishing between ARI’s Hypot, HypotUltra, and HypotMax: Which device is right for your factory?
07/13/2026 09:48:30

Few people realize that the concept of the "Hipot Test"—or electrical safety testing—has long existed within the electrical equipment manufacturing industry. Driven by the growing need to verify the voltage withstand capabilities of conductors, motors, and electrical devices, the industry required a robust and virtually fail-safe method to detect insulation weaknesses before products reached the market.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts