Output Voltage: 19V
Output Load: 6.32A
Output Regulation: 2%
Output Power: 120W
Line & Load Regulation %: See model selector
Ripple & Noise: 1%
Hold Up Time (typical): 16ms (Full load at 115VAC input)
Overcurrent Protection: 105 - 120%
Overvoltage Protection: 110 - 130%, cycle AC line to reset
Input Voltage Range: 90-264 VAC, 47-63 Hz (440Hz with reduced PFC)
AC Input Current: 2.5A Max
Harmonic Correction (PFC): Meets EN61000-3-2 (typically >0.9)
Efficiency: Typically 85% full load at nominal AC Line
Inrush Current Limiting: <50A peak @ 230VAC cold start
Leakage Current: <0.75mA (264VAC, 60Hz)
Cooling: Convection
Withstand Voltage: Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VDC
Isolation Resistance: >20M at 25°C & 70%RH, Output to Ground 500VDC
Operating Temperature: 0 to +40°C, derate linearly to 50% load from 40°C to 60°C
Temperature Coefficient: ±0.05%/°C
Storage Temperature: -10 to +70°C
Humidity (non-condensing): 20-90%RH operating, 20-95%RH non-operating
Shock: < 196.1m/s2 (20G)
Vibration: 10Hz-55Hz amplitude (sweep 1 min), <2G X, Y, Z axis for 1 hour each
Altitude: 2000m operating, 5000m storage
Size W x L x H in: 3 x 5 x 1.27”
Weight g: 300