For full functionality of this site it is necessary to enable JavaScript.
EMIN.COM.MM
0

6 Series B MSO Mixed Signal Oscilloscope

10/01/2020 15:16:09

Troubleshoot and validate high-speed designs with bandwidth that starts at 1 GHz and goes up to 10 GHz . Get accurate measurements with low noise and sample rate up to 50 GS/s . See more of your design with 6- and 8-channel models...

 
 

Get to know the 6 Series B

- Performance specifications

- A new standard in usability

- Built-in measurements and analysis

- Tackling high-speed clocks and data

- Multi-channel spectrum analysis

- From 3 V power rails to 3-phase drives





Synchronized multi-channel spectrum analysis

Get 4, 6 or 8 channels of spectrum analysis. Hardware digital downconverters (DDCs) in parallel with time domain signal processing unlock exciting capabilities.

- Any analog channel can be viewed as a waveform, spectrum, or both

- Plot and trigger on changes in RF frequency or magnitude

- Spectrums and time domain waveforms are synchronized to correlate RF and time domain events

- Spectrum controls such as center frequency and RBW are completely independent of time domain controls


Advanced analysis simplified

Characterize jitter on GHz clocks and serial buses with ease. Bring statistics into your everyday toolkit with integrated measurements. Use the same simple drag and drop action to add advanced and everyday measurements.

- Automated measurements and trend analysis

- Spectrum View synchronized multi-channel spectrum analysis

- Advanced jitter analysis

- Advanced power analysis

- Power rail measurements

- Memory analysis and debug

- High-speed serial compliance



Fidelity begins at the probe tip

- With 4, 6 or 8 FlexChannel® inputs you can browse your circuits with the included 1 GHz probes. Connect high performance single-ended active probes or differential probes, or do both at once with TriMode probes. Connect a TLP058 logic probe and get 8 digital channels on any FlexChannel input to expand your system visibility.

- Built-in 1 MΩ and 50 Ω input terminations

- 1 GHz low-loading passive probe for each input, included

- TekVPI probe interfaces with 10W of probe power per channel for differential, current, power rail, and optically isolated probes

- TDP7700 Series 4, 6, 8 and 10 GHz TriMode probes -- perfect for measuring high-speed communications




Specification Overview


Input Channels

4,6 or 8 FlexChannel inputs.

Each FlexChannel provides 1 analog signal input or 8 digital logic inputs with TLP0581 probe

Signal Generator 1

13 standard waveform types, plus arbitrary

 

Digital Voltmeter 2

4 digit

 

Bandwidth 1

1, 2.5, 4, 6, 8, 10 GHz

 

Trigger Frequency Counter 2

8 digit

Sample Rate

50 GS/s on 2 analog channels

25 GS/s on 4 analog channels

12.5 GS/s on > 4 analog channels

Display

15.6-inch (385 mm)

TFT color HD (1920 x 1080) resolution Capacitive (multi-touch) touchscreen

 

Record Length 1

Up to 1 Gpoints on all analog/digital channels

1 - Optional and upgradeable

2 - Free with product registration



Add capability as soon as you need it

- Add bandwidth up to 10 GHz

- Increase record length up to 1 Gpoints on each channel

- Add logic probes for up to 64 digital channels

- Add a Windows 10 operating system

- Add an Arbitrary / Function Generator

- Add advanced analysis: serial decode/trigger, power, jitter, memory analysis and debug, and automated compliance testing

- Choose from a wide range of voltage and current probes




What's in the box?

- One TPP1000 1 GHz, low-C passive probe for each channel, with accessories

- Front cover with accessory pouch

- Mouse

- Power cord

- Printed Installation Manual covers safety and basic operation

- Comprehensive built-in online help

- Certificate of traceability

- 1-year warranty on the instrument and included probes


Related News

Which Vacuum Pump Should You Choose for a Microbiology Lab to Avoid Affecting Samples?
07/15/2026 14:45:07

Vacuum pumps are utilized in a wide range of microbiology laboratory procedures, from membrane filtration and the aspiration of supernatants following centrifugation to sample concentration and the support of negative-pressure systems. Selecting the appropriate pump not only ensures more stable operational processes but also minimizes the risk of sample contamination, reduces maintenance costs, and extends the equipment's lifespan

QCVN 25:2025/BKHCN Takes Effect: Do Businesses Need to Prepare Electrical Safety Testing Equipment?
07/15/2026 09:15:04

Electrical safety is consistently one of the primary criteria evaluated before electrical or electronic equipment—or industrial components—are released to the market. A product may operate reliably yet still fail to meet requirements if its insulation lacks sufficient durability, its grounding resistance exceeds permissible limits, or leakage current occurs during operation.

Why Is Associated Research Considered an Icon of Hipot Technology?
07/14/2026 09:05:30

When it comes to electrical safety testing equipment specifically Hipot testers—many QA/QC and testing engineers are familiar with the globally renowned brand Associated Research. A subsidiary of the parent company IKONIX, Associated Research (ARI) invented the world's first commercial Hipot tester.

What Is the Standard 3-Phase Voltage? How to Read Cabinet-Mounted Meters Without Errors
07/13/2026 15:09:18

Voltmeters are almost invariably found on the panels of electrical cabinets in factories, power stations, or generator systems. A glance lasting just a few seconds allows an operator to determine whether the power supply is stable or showing signs of abnormality. However, not everyone understands the significance of the displayed readings, particularly regarding three-phase electrical systems.

Distinguishing between ARI’s Hypot, HypotUltra, and HypotMax: Which device is right for your factory?
07/13/2026 09:48:30

Few people realize that the concept of the "Hipot Test"—or electrical safety testing—has long existed within the electrical equipment manufacturing industry. Driven by the growing need to verify the voltage withstand capabilities of conductors, motors, and electrical devices, the industry required a robust and virtually fail-safe method to detect insulation weaknesses before products reached the market.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts